Zapi COMBI AC1 Manuel d'utilisateur Page 17

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 86
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 16
AMPSEAL VERSION
U VERY IMPORTANT
It is necessary to specify in the order the type of encoder used, in terms of
power supply, electronic output and n° of pulses for revolution, because
the logic unit must be set in the correct way by Zapi.
The n° of pulses revolution the controller can handle is given by the
second-last letter in the software release name (see 3.5).
4.2.6 Main contactor and key connection
- The connection of the main contactor can be carried out following the
drawing in the figure.
AMPSAAB VERSION
AMPSEAL VERSION
- The connection of the battery line switches must be carried out following
ZAPI instructions.
If a mechanical battery line switch is installed, it is strongly recommended
that the key supply to the inverter is open together with power battery line
(see picture below); if not, the inverter may be damaged if the switch is
-
opened during a regenerative braking.
- An intrinsic protection is present inside the logic when the voltage on the
battery power connection overtakes 40% more than the battery nominal
AEQZP0BA – COMBI AC1 - User Manual Page - 17/86
Vue de la page 16
1 2 ... 12 13 14 15 16 17 18 19 20 21 22 ... 85 86

Commentaires sur ces manuels

Pas de commentaire